| Profile 01 | Western Europe | Cast-resin distribution and dry-type power transformers | Up to approximately 36 kV | Approximately 100 kVA to 25 MVA | Vacuum pressure casting with flame-retardant epoxy systems | IEC 60076, IEC 60076-11, IEC 60270 | Commercial buildings, industrial plants, renewable-energy substations | Routine, type, temperature-rise, partial-discharge and acoustic-noise tests |
| Profile 02 | East Asia | Medium-voltage cast-resin transformers and compact substations | 3.3 kV to 35 kV class | Approximately 50 kVA to 20 MVA | Encapsulated windings using glass-fiber-reinforced epoxy resin | IEC 60076-11, IEEE C57.12.01, IEC 60296 where applicable | Data centers, metro systems, factories and utility distribution | Impulse, dielectric withstand, ratio, winding-resistance and partial-discharge testing |
| Profile 03 | North America | Dry-type transformers for commercial and industrial power systems | 600 V to 35 kV class | Approximately 75 kVA to 15 MVA | Cast-coil insulation designed for low flammability and low maintenance | IEEE C57.12.01, IEEE C57.96, NEMA and applicable CSA requirements | Hospitals, universities, manufacturing facilities and infrastructure projects | UL or CSA-related evaluation, thermal testing, insulation tests and load-loss verification |
| Profile 04 | Southern Europe | Cast-resin transformers for renewable-energy and grid projects | Up to approximately 40.5 kV | Approximately 100 kVA to 30 MVA | Thermal-shock-resistant epoxy encapsulation for variable-load duty | IEC 60076 series, IEC 60076-11 and EcoDesign requirements where applicable | Solar farms, wind farms, battery storage and distribution substations | Load-cycle testing, partial-discharge measurement, environmental checks and efficiency testing |
| Profile 05 | Central Europe | High-efficiency dry-type transformers and special-purpose units | Up to approximately 36 kV | Approximately 160 kVA to 25 MVA | Resin-rich or vacuum-cast insulation with optimized thermal performance | IEC 60076-11, IEC 60076-12 and relevant national installation codes | Railway power, marine facilities, industrial drives and public infrastructure | Loss measurement, temperature-rise, impulse, electromagnetic compatibility and vibration testing |
| Profile 06 | South Asia | Distribution transformers and project-specific dry-type transformers | Up to approximately 33 kV | Approximately 100 kVA to 12.5 MVA | Flame-retardant epoxy cast coils for indoor and harsh-site installations | IEC 60076, IS 11171 and IEEE requirements according to destination market | Industrial parks, commercial complexes, utilities and transport networks | Routine production tests, insulation resistance, dielectric tests and no-load/load-loss tests |
| Profile 07 | Southeast Asia | Compact cast-resin transformers for urban and industrial applications | 6.6 kV to 24 kV class | Approximately 100 kVA to 10 MVA | Moisture-resistant epoxy systems suitable for humid operating environments | IEC 60076-11, IEC 60270 and local utility specifications | High-rise buildings, semiconductor facilities, ports and industrial estates | Humidity checks, partial-discharge tests, dielectric withstand and dimensional inspection |
| Profile 08 | Middle East | Dry-type transformers for high-temperature and dusty environments | Up to approximately 36 kV | Approximately 250 kVA to 20 MVA | High-temperature-rated epoxy insulation with reinforced mechanical protection | IEC 60076-11, IEC 60529 and project-specific utility standards | Oil and gas facilities, airports, desalination plants and utility substations | Temperature-rise, enclosure protection, dielectric, partial-discharge and heat-cycle tests |
| Profile 09 | Latin America | Medium-voltage distribution and industrial dry-type transformers | Up to approximately 34.5 kV | Approximately 75 kVA to 15 MVA | Encapsulated epoxy windings for reduced fire and fluid-leakage risk | IEC 60076-11, IEEE C57.12.01 and applicable national standards | Mining, pulp and paper, food processing, utilities and commercial facilities | Routine, induced-voltage, applied-voltage, ratio and load-loss testing |
| Profile 10 | Oceania and Export Markets | Specialized dry-type transformers and renewable-energy units | Up to approximately 33 kV | Approximately 100 kVA to 20 MVA | Low-maintenance cast-resin insulation for indoor, coastal and remote installations | IEC 60076-11, AS/NZS 60076 and destination-market requirements | Mining operations, wind and solar projects, ports and remote networks | Salt-mist or environmental testing where specified, dielectric, thermal and partial-discharge tests |