| Supplier Profile 01 | Six-pulse thyristor | 3-phase, 380–415 VAC, 50/60 Hz | 0–12 V DC / 0–24 V DC | 1,000–10,000 A | Automatic shutdown and alarm | Forced-air cooling | Constant-current and constant-voltage modes | Overcurrent, overvoltage, short circuit, overtemperature | IP21–IP31 | 4–8 weeks | 12 months | General chrome-plating lines | 8.6 / 10 |
| Supplier Profile 02 | Six-pulse diode | 3-phase, 380–460 VAC, 50/60 Hz | 0–18 V DC | 500–5,000 A | Phase monitoring relay with contactor trip | Air cooling | Manual voltage and current adjustment | Input phase loss, fuse failure, overtemperature | IP20–IP31 | 3–6 weeks | 12 months | Cost-sensitive standard installations | 8.1 / 10 |
| Supplier Profile 03 | Twelve-pulse thyristor | 3-phase, 380–415 VAC, 50 Hz | 0–24 V DC | 2,000–20,000 A | Redundant phase-loss sensing and alarm output | Air-to-water heat exchanger | Closed-loop current regulation | Input surge, DC overcurrent, water-flow alarm, overtemperature | IP31–IP54 | 8–14 weeks | 18 months | Large high-current plating systems | 9.2 / 10 |
| Supplier Profile 04 | Six-pulse IGBT | 3-phase, 380–480 VAC, 50/60 Hz | 0–30 V DC | 300–3,000 A | Digital phase-sequence and phase-loss protection | Forced-air cooling | Programmable current and voltage control | Short circuit, DC ripple limit, thermal alarm, emergency stop | IP21–IP42 | 6–10 weeks | 12 months | Precision and low-ripple chrome plating | 8.8 / 10 |
| Supplier Profile 05 | Six-pulse thyristor | 3-phase, 380–440 VAC, 50 Hz | 0–15 V DC | 1,000–8,000 A | Phase-loss relay and input fuse protection | Air cooling | Analog current control | Overcurrent, overvoltage, transformer temperature | IP20–IP31 | 4–7 weeks | 12 months | Standard hard-chrome production tanks | 7.8 / 10 |
| Supplier Profile 06 | Twelve-pulse diode | 3-phase, 380–415 VAC, 50 Hz | 0–20 V DC | 2,000–12,000 A | Input monitoring with automatic output isolation | Water cooling | Fixed-voltage or fixed-current configuration | Water-flow, overtemperature, DC short circuit, phase loss | IP31–IP54 | 8–12 weeks | 12 months | High-duty industrial plating lines | 8.7 / 10 |
| Supplier Profile 07 | Six-pulse IGBT | 3-phase, 380–460 VAC, 50/60 Hz | 0–24 V DC | 500–4,000 A | Software alarm, hardware trip, and event logging | Forced-air cooling | Digital closed-loop regulation | Phase loss, phase reversal, overload, overtemperature, communication fault | IP21–IP42 | 6–9 weeks | 18 months | Automated lines requiring process traceability | 9.0 / 10 |
| Supplier Profile 08 | Six-pulse diode | 3-phase, 380–415 VAC, 50 Hz | 0–12 V DC | 300–2,500 A | Phase-loss relay with warning lamp | Natural or forced-air cooling | Manual tap or potentiometer adjustment | Input fuse, output fuse, overtemperature | IP20–IP31 | 3–5 weeks | 12 months | Small and medium plating workshops | 7.6 / 10 |
| Supplier Profile 09 | Twelve-pulse thyristor | 3-phase, 380–415 VAC, 50/60 Hz | 0–30 V DC | 3,000–30,000 A | Dual phase-loss detection with interlock circuit | Water cooling | Programmable ramp-up and current limiting | Overcurrent, phase loss, cooling failure, ground fault, emergency trip | IP42–IP54 | 10–16 weeks | 18 months | Continuous-duty heavy industrial applications | 9.1 / 10 |
| Supplier Profile 10 | Modular IGBT | 3-phase, 380–480 VAC, 50/60 Hz | 0–40 V DC | 200–2,000 A per module | Per-module phase monitoring and system shutdown | Forced-air cooling | Digital current, voltage, and pulse control | Module failure, overcurrent, overtemperature, phase loss, communication fault | IP21–IP42 | 7–12 weeks | 12–18 months | Expandable lines and multi-tank systems | 8.9 / 10 |