| Body-Tinted Annealed Float Glass | Commonly 3–12 mm; confirm availability for the required color and sheet size. | Color is incorporated into the glass body. It can be cut and processed after manufacture, but it is not safety glazing unless further processed. | Check color consistency between production batches, visible light transmission, solar heat gain, edge appearance, and the effect of the glass color on interior finishes. | ASTM C1036 for flat glass; EN 572-2 for basic soda-lime-silicate glass products. | Use a fully supported frame with resilient setting blocks and compatible glazing gaskets. Do not use as safety glazing in doors, sidelights, or hazardous locations without additional treatment. | Cabinet doors, framed partitions, decorative panels, wall features, and low-impact interior glazing. |
| Body-Tinted Tempered Glass | Commonly 4–12 mm; the required edgework and holes must be specified before tempering. | Heat-treated for increased mechanical and thermal resistance. When broken, it generally breaks into smaller particles. Tempered glass cannot be cut, drilled, or altered after tempering. | Confirm that all dimensions, holes, notches, polished edges, and surface treatments are finalized before heat treatment. Check thermal-stress exposure and required safety-glazing classification. | ASTM C1048; ANSI Z97.1 and 16 CFR 1201 where safety glazing compliance is required; EN 12150-1 in European applications. | Use an approved framing or fixing system designed for tempered glass. Keep glass separated from metal, stone, and other hard surfaces with suitable setting materials. | Doors, shower enclosures, partitions, furniture panels, balustrade infill, and areas subject to impact or temperature changes. |
| Body-Tinted Heat-Strengthened Glass | Commonly 4–12 mm; actual availability depends on processing capability. | Has greater resistance to thermal stress than annealed glass, but it is not equivalent to fully tempered glass. Broken pieces are usually larger than those from tempered glass. | Determine whether the project requires safety glazing. Check thermal gradients, solar exposure, frame movement, and the risk of thermal breakage. | ASTM C1048; EN 1863-1 for heat-strengthened glass. | Install with proper edge clearances and flexible glazing materials. Use laminated construction where post-breakage retention or safety performance is required. | Large fixed windows, façades with thermal exposure, and applications where lower distortion than fully tempered glass is preferred. |
| Colored Laminated Glass | Typical constructions include 6.38 mm, 8.38 mm, and 10.38 mm, depending on glass plies and interlayer thickness. | Consists of two or more glass plies bonded by an interlayer. The interlayer can provide color, sound reduction, UV filtering, and retention of fragments after breakage. | Check interlayer compatibility with sealants, edge exposure, humidity, UV exposure, required color stability, acoustic targets, and whether the assembly must be safety glazing. | ASTM C1172; ANSI Z97.1 and 16 CFR 1201 where applicable; EN 14449 for laminated glass. | Protect exposed edges from moisture unless the system is specifically designed for exposed-edge use. Use sealants and gaskets confirmed as compatible with the interlayer. | Overhead glazing, railings, façades, entrance areas, acoustic partitions, and decorative installations requiring retained fragments. |
| Colored Ceramic-Frit Glass | Commonly 4–12 mm; frequently supplied as tempered or heat-strengthened glass. | Fired ceramic color is permanently fused to the glass surface. It can provide opaque or translucent patterns and can reduce glare and solar transmission depending on coverage. | Confirm frit coverage, color density, viewing distance, surface orientation, thermal-stress conditions, and whether the frit is on the protected or exposed face. | Use the base-glass standard, such as ASTM C1048 or EN 12150-1 when heat-treated; project-specific façade or safety requirements may also apply. | Complete cutting, drilling, edge finishing, and frit firing before final tempering. Follow the specified orientation and avoid abrasive contact with the frit surface. | Façades, screens, spandrel areas, partitions, privacy panels, and decorative architectural glazing. |
| Coated or Reflective Colored Glass | Commonly 4–12 mm for monolithic products; insulated units may use multiple panes. | A surface coating changes color, reflectance, solar control, or emissivity. Coatings may be more sensitive to scratching, edge exposure, and chemical attack than body-tinted glass. | Identify the coated surface, check whether the coating is suitable for exposed use, verify sealant compatibility, and confirm reflectance, visible transmission, and solar-performance requirements. | Use the base-glass standard plus the applicable coating, insulating-glass, and safety-glazing requirements; ASTM C1376 is commonly referenced for coated architectural flat glass. | Protect the coated surface during handling and cleaning. For insulated glazing, place the coating in the specified cavity or protected position and use a compatible edge-seal system. | Energy-conscious façades, curtain walls, windows, commercial interiors, and applications requiring controlled reflectance or solar gain. |
| Colored Insulating Glass Unit | Overall unit thickness commonly ranges from approximately 16–40 mm, depending on pane thickness and cavity width. | Combines two or more panes with a sealed gas or air space to improve thermal performance. The colored pane affects daylight, solar gain, and visual appearance. | Check cavity width, spacer type, gas fill, condensation resistance, coating position, color uniformity, sealant compatibility, and frame rebate depth. | ASTM E2190 for insulating glass unit performance; EN 1279 series in European applications; safety requirements apply to individual panes. | Provide adequate drainage and support. Maintain edge clearances and avoid structural loads on the glass. Confirm the unit thickness before ordering frames or hardware. | Exterior windows, curtain walls, skylights, and façades where thermal and solar-control performance is important. |
| Colored Glass for Wet or High-Humidity Areas | Thickness should be selected according to the backing, span, fixing method, and impact requirements; 6–10 mm is common for interior panels. | Performance depends heavily on edge protection, backing materials, adhesive selection, and ventilation. Laminated or tempered construction may be required by location. | Test compatibility with silicone, neutral-cure sealants, cementitious substrates, waterproofing membranes, cleaners, and moisture exposure. Check whether the color layer is moisture-sensitive. | Apply the relevant base-glass and safety-glazing standards; installation materials should be evaluated for the intended wet-area exposure. | Use non-staining, glass-compatible sealants and allow movement joints. Avoid trapping water behind the sheet and follow the adhesive manufacturer’s curing requirements. | Bathrooms, kitchen backsplashes, spa areas, shower walls, and other interior wet-zone applications. |
| Colored Glass for Overhead or Exterior Exposure | Thickness must be calculated from span, support conditions, wind or snow loads, impact risk, and local building requirements. | Overhead and exterior glazing can be exposed to wind, thermal gradients, moisture, ultraviolet radiation, and falling-object impact. Laminated safety glass is commonly required for overhead locations. | Verify structural load calculations, safety-glazing classification, solar exposure, thermal-stress risk, water management, UV resistance, and long-term sealant compatibility. | Use applicable structural and safety standards, such as ASTM C1036, ASTM C1172, ASTM C1048, ASTM E1300, ANSI Z97.1, or the relevant local code. | Use an engineered support system, proper drainage, compatible setting blocks, and specified edge clearances. Do not select thickness based only on appearance. | Skylights, canopies, exterior screens, façades, overhead walkways, and exposed architectural features. |